- INTERNAL and TRUNK CALLER LINE identification IN BOTH FSK and DTMF MODE, FLEXIBLE EXTENSION NUMBERING (1-4 DIGITS), INCOMING CALL RING and OUTGOING CALL CAN BE PROGRAMMED EXTENSION WISE
- CALL TRANSFER TO OTHER EXTENSIONS, MEMORY DIALING FACILITY UPTO 48 NUMBERS, CONFERENCE BETWEEN TELEPHONE MAIN LINE and 2 EXTENSIONS; CONNECTS TO DOOR PHONE (OPTIONAL)
- CONNECTS TO 2 TELEPHONE LINE and 16 EXTENSIONS, BEST IN CLASS HOLD MUSIC, WELCOME MESSAGE FOR 10 SEC, BUSY MESSAGE FOR 5 SEC and NO ANSWER MESSAGE FOR 5 SEC
- DAY/NIGHTS MODE FACILITY, PLUG AND PLAY PBX WITH COMPACT BODY and ROBUST design
- This Package Includes
- CCL216=1pcs
- C11=16pcs
Every call, connected.
The CCL 216 connects 2 outside telephone lines to 16 internal phones. Every phone can call every other phone free by dialling its extension number, and all phones share the outside lines for incoming and outgoing calls. It suits offices, guest houses and showrooms.
In this kit
1 x CCL 216 system and 16 x Beetel C11 basic phones (no caller ID screen). Ready to wire and use.
Room to grow
Every extension port is used by the phones in this kit.
Want caller ID?
This system supports caller ID, but C11 phones have no screen. Swap in Beetel C51 or M71 phones where you want to see the caller.

Who it suits.
Size
Plan for about 20 percent more phones than you have today. This system fits up to 16 phones and 2 lines.
Features
Call transfer, hold, call pickup and day / night mode, plus an inbuilt welcome message, hold music and internal and trunk caller ID. See the feature list above for this exact model.
Add-ons
No landline? Add a GSM gateway to use a mobile SIM as a line. Add a door phone and lock kit to open the gate from any phone.
How to install.
- Mount the unit on a dry, ventilated indoor wall near the telephone line socket and a power point.
- Cable each phone point back to the system with 2-core telephone cable. Keep it 30 cm away from mains wiring and label both ends.
- Terminate with a rosette at each phone; use an MDF box when you have 8 or more phones.
- Connect outside lines to the LINE / CO ports and each extension cable to an EXT port.
- Power it up; add a 24 V battery set (two 12 V 7 Ah) on CCL systems for power-cut backup.
- Test extension to extension and an outside call, then programme extension numbers and restrictions from the manual.

Questions, answered.
Can I use it without an outside line?
Yes. It works as an internal intercom with no line connected.
Which phones work with it?
Any standard analogue phone in tone or pulse mode. Use caller ID phones such as the Beetel C51 or M71 where you want to see who is calling.
Will it work in a power cut?
With a battery set connected, yes. CCL systems use 24 V (two 12 V 7 Ah batteries).
How far can phones be from the system?
Hundreds of metres on good 2-core telephone cable. CCL specifies under 600 ohms loop resistance per extension.