SGM-750 Sliding Gate Motor – Setup Guide

Setup guide · SGM-750

Install and set up the OTOMATE SGM-750 sliding gate motor (750 W, gates up to 1,500 kg). Fit the motor, fix the gear rack, set the limits and open your gate by remote.

OTOMATE SGM-750 sliding gate motor, side view with drive gear

What’s in the box

  • Sliding gate motor with built-in control board
  • 2 remotes
  • Limit switches
  • 2 manual release keys
  • Mounting base plate
  • User manual
The SGM-750 is sold as “Motor only”. The gear rack is not included: add GR-12M gear racks (1 m each) to cover the full length of your moving gate.

Tools you’ll need

  • Drill with masonry bit
  • Anchor bolts or J-bolts and concrete
  • Spirit level and measuring tape
  • Spanner and screwdriver set
  • Welding machine or bolts to fix the gear rack
  • Outdoor-rated power cable from an MCB (220 V AC, 50 Hz)

Install

Gate motor installation involves mains power and heavy moving parts. We recommend a trained technician and electrician.

  1. Check the gate first.The gate must slide freely by hand along its whole track, with no tight spots. Its moving weight must be under 1,500 kg. If it is close to the limit, use a bigger model.
  2. Pick the motor position.Place the motor inside the property, beside the gate, so the gear rack on the gate passes over the motor’s pinion for the full opening.
  3. Make a firm, level base.Cast a small concrete block or use a solid floor. Fix the base plate with anchor bolts. Check it is level both ways.
  4. Fix the motor on the base plate.Tighten the nuts so the motor cannot move. The pinion should face the gate.
  5. Release the motor.Open the release cover and turn the key to unlock the clutch. The gate can now be pushed by hand.
  6. Fit the gear rack.Rest the first rack piece on the pinion and fix it to the gate. Slide the gate and fix the next piece in line, until the rack covers the full travel.
  7. Set the rack gap.Leave a small gap (about 1–2 mm) between rack and pinion along the whole length, so the gate’s weight does not rest on the motor. Slide the gate by hand to check it runs smoothly.
  8. Fit the limit switch parts.Fix the limit magnets or cams on the rack at the fully open and fully closed positions, as shown in the manual in the box. Do not let the gate hit its end stops.
  9. Connect power.Your electrician runs a 220 V AC supply from a dedicated MCB with earth to the control board. Follow the terminal labels on the board and the manual in the box.
  10. Lock the clutch.Turn the release key back to lock and close the cover. Move the gate slightly by hand until the gear engages.
Wire colours, terminal names and DIP or jumper settings differ between board versions. Always follow the label on the control board and the manual in the box.

First-time setup

First run and direction check

  1. Stand clear of the gate and switch on the MCB.
  2. Press a remote button once. Watch which way the gate moves.
  3. If it moves the wrong way, switch off the MCB and change the motor direction as shown in the manual in the box.
  4. Run the gate to fully open and fully closed. It must stop at each end by itself.
  5. If it stops too early or too late, switch off and move the limit magnet or cam a little. Test again.

Remotes

  1. The 2 remotes in the box come ready to use.
  2. To add an extra RM-SGM remote, use the learn button on the control board as described in the manual in the box.
  3. Give one remote to each driver. Keep the remotes away from children.
Want app control or a safety beam? The WFC-SGM Wi-Fi module and SB-10 safety beam can be added at any time. A safety beam stops the gate from closing on a car or a person.

Daily use

  1. Press the remote to open the gate. Press again to stop or close, as set on your board.
  2. Always watch the gate while it moves. Keep people, pets and vehicles clear.
  3. In a power cut, open the release cover, unlock with the key and slide the gate by hand. Lock it again when power returns.
  4. Every few months, clean the rack and track, and check that the base bolts and rack fixings are tight.

Troubleshooting

Problem Try this
Remote does nothing Check the remote LED. Replace the battery. Come closer to the gate. If it still fails, pair the remote again.
Motor hums but the gate does not move Check the clutch is locked with the key. Look for a stone or debris in the track. Push the gate by hand to find tight spots.
Gate does not stop at the end Check the limit magnet or cam is in place and within reach of the limit switch. Adjust its position.
Gate stops or reverses midway Something may be blocking the safety beam, if fitted. Clean and align the beam. Check the track for obstructions.
Motor stops after many runs and starts again later The thermal cut-out (125 °C) has tripped to protect the motor. Let it cool. Reduce back-to-back runs.
Noise or jerky movement Check the 1–2 mm gap between rack and pinion along the whole gate. Re-align rack pieces and clean the track.
No power at all Check the MCB and the supply at the board. Have an electrician check the wiring.

Safety

  • Switch off the MCB before opening the motor cover or doing any work.
  • Mains wiring must be done by a trained electrician, with a proper earth.
  • Never let children play with the gate or the remotes.
  • Operate the gate only when you can see it.
  • The motor is IP55 (dust and water jets). Do not install it where water collects.
  • Fit end stops on the track so the gate can never run off its rail.

Manuals, videos and product page

Video guides

Installation and setup videos for NavKar products.

Watch on YouTube
SGM-750 product page

Specifications, photos and accessories.

View product

Still need help?

Warranty terms are as stated on your bill and on the product page. Keep your bill safe; we need it for any warranty claim. Free setup support is available on call and WhatsApp.

Send us your model, purchase date and a photo or short video of the problem. WhatsApp +91 91384 68548, Mon–Sat 10:00–5:30.

Chat on WhatsAppAll manuals