SMK-43 – Wireless Smoke Sensor
Wireless Smoke Sensor
- Buy on Amazon: CLICK HERE TO BUY ON AMAZON
- Buy on website: CLICK HERE TO BUY ON Website
Product Overview
The SMK-43 Wireless Smoke Detector Smart Fire Alarm is designed to provide early warning of smoke and potential fire hazards in residential and commercial spaces. It uses a high-sensitivity smoke detection sensor to monitor the surrounding area and provides a loud siren alert when smoke is detected.
Its wireless design and easy installation make it suitable for adding smoke protection to different areas without extensive wiring. The detector can be used in homes, offices, kitchens and other suitable indoor locations.
Main Purpose
The SMK-43 is designed to detect smoke at an early stage and provide an audible warning, helping occupants respond quickly to a potential fire emergency.
Key Benefits
- High-Sensitivity Smoke Detection – Designed to detect smoke and provide an early warning.
- Loud Siren Alert – Produces an audible alarm when smoke is detected.
- Wireless Design – Helps simplify installation without extensive signal wiring.
- Easy Installation – Suitable for quick installation in appropriate indoor locations.
- Indoor Protection – Helps improve fire-safety awareness in homes, offices and other suitable areas.
Important Features
- Wireless smoke detector
- High-sensitivity smoke sensor
- Loud audible siren
- Easy installation
- Compact design
- Suitable for home and office use
- Suitable for kitchen applications where permitted by the manufacturer's installation guidelines
- Designed for indoor smoke detection and early warning
Product Specifications
- Model: SMK-43
- Product Type: Wireless Smoke Detector / Smart Fire Alarm
- Brand: NAVKAR SYSTEMS
- Power Supply: 9V Alkaline Battery or Carbon Battery
- Communication: Wireless RF – 433MHz / 1527 / 330K, Selectable
- Operating Range: [Range]
- Material: [Material]
- Dimensions: 11.5 x 11.2 x 5.5 cm
- Other Specifications: Photoelectric smoke detection, alarm sound >80 dB, static current ≤18 µA, alarm current <200 mA, working temperature 0°C to 50°C, relative humidity ≤95% RH non-condensing, wireless operation, audible and visual alarm, low-voltage warning, weekly TEST function, indoor installation only.
Applications
- Home Fire Safety – Detects smoke and provides an audible and visual warning during a potential fire event.
- Office & Workplace Safety – Suitable for indoor smoke detection in offices and workplaces.
-
Residential & Commercial Premises – Can be used in suitable indoor areas requiring wireless smoke detection.
Suitable For
- Indoor residential and commercial premises
- Ceiling-mounted installation
-
Locations requiring wireless smoke detection and alarm signaling
Not Suitable For
- Outdoor installation – The manual specifies indoor use and installation only.
- Bathrooms, water-prone or water-dripping areas – Do not install in locations exposed to water.
- Areas with smoke or steam generation – Avoid non-hazardous smoke- or steam-producing locations.
- Extreme temperatures – Do not install where the temperature is below 0°C or above 50°C.
-
Near ventilation equipment – Keep the detector at least 150 cm away from ventilation fans, air conditioners and vents.
Package Contents
- 1 × SMK-43 Wireless Smoke Detector
- 1 × Mounting Plate / Base
- 1 × Mounting Hardware Set – Screws and wall plugs
-
1 × User Manual
Installation
-
Step 1 – Select a Suitable Location
Install the detector indoors in a suitable location. Keep it at least 50 cm away from lighting appliances, and at least 150 cm away from ventilation fans, air conditioners and vents. If installed close to a cabinet/ceiling obstruction, maintain the specified clearance of 60 cm. -
Step 2 – Install the Mounting Plate
For screw installation, drill the required holes in the ceiling, insert the plastic expansion nuts and secure the mounting plate using the supplied self-fastening screws. -
Step 3 – Attach the Detector
Align the back of the detector with the mounting plate and rotate it clockwise until you hear a “snap” sound indicating that it is installed correctly. -
Step 4 – Power and Test the Detector
Install the required battery before mounting the detector onto the installation plate. Press the TEST button to confirm that the detector produces the expected alarm response.
Wiring
The SMK-43 is a battery-powered wireless smoke detector, so external power or signal wiring is not required.
- Power: 9V alkaline battery or carbon battery
- Input: Smoke detection through the built-in photoelectric smoke-detecting sensor
- Output: Audible and visual alarm + wireless alarm signal
- Other Connections: Wireless communication at 433MHz / 1527 / 330K, selectable according to the product configuration.
Programming
-
Step 1 – Select the Required Wireless Frequency
The manual specifies selectable wireless frequencies of 433MHz / 1527 / 330K. -
Step 2 – Register with the Compatible Alarm System
Where the detector is being used as part of a wireless alarm system, register/configure it according to the compatible alarm panel's sensor-learning procedure. -
Step 3 – Test the Wireless Alarm Signal
Press the TEST button and confirm that the detector sends the wireless alarm signal to the compatible alarm system.
Operation
-
Step 1 – Normal Monitoring
During normal operation, the detector monitors the surrounding area for smoke. The LED blinks once every 90 seconds and there is no alarm sound. -
Step 2 – Smoke Detection
When smoke is detected, the LED blinks continuously and the detector produces a quick beep alarm. -
Step 3 – Wireless Alarm Transmission
The detector provides an audible/visual alarm and sends a wireless alarm signal to the compatible alarm system.
Troubleshooting
-
Problem 1: Detector does not power on
Solution: Check that the 9V battery is installed correctly and has sufficient power. Replace the battery if required. -
Problem 2: Detector gives unwanted alarms
Solution: Check the installation location. Keep the detector away from areas producing steam or non-hazardous smoke and maintain the recommended distance from ventilation equipment and lighting appliances. -
Problem 3: Wireless signal is not received by the alarm panel
Solution: Check that the detector's wireless frequency is compatible with the alarm panel and that the detector is within the specified wireless range. The manual specifies a wireless distance of ≥100 m in open space.
Common Problems
- Low Battery – Replace the battery with a new battery having the same parameters when the low-voltage warning occurs.
- False Alarm – Move the detector away from steam, smoke-producing areas and unsuitable environmental conditions.
-
Poor Wireless Communication – Check the wireless frequency/configuration and ensure the detector is within the supported open-space transmission distance.
Maintenance
- Weekly Testing: Press the TEST key once every week after installation and during use.
- Regular Inspection: Inspect the detector regularly and arrange factory repair if a malfunction is identified.
- Battery Maintenance: The manual states that the battery has an expected lifespan of approximately 1 year under normal conditions, which may be shorter in high-temperature or high-humidity environments.
- Cleaning & Protection: Keep the detector clean and protect it from dust, moisture and corrosion.
- Battery Replacement: Replace the battery with a new one having the same parameters when the detector indicates low voltage.
Technical Specifications
- Power Supply: 9V alkaline battery or carbon battery
- Static Current: ≤18µA
- Alarm Current: <200mA
- Wireless Distance: ≥100 m in open space
- Frequency: 433MHz / 1527 / 330K, selectable
- Working Temperature: 0°C to 50°C
- Relative Humidity: ≤95% RH, non-condensing
- Alarm Sound: >80 dB
- Independent Mode: Sound and light alarm only
- Dimensions: 106 × 106 × 41.5 mm
- Mounting Base Dimension: Approximately 71 mm
- Operating Principle: Photoelectric smoke detection
Important: The manual states that the detector cannot be mounted onto the installation plate without the battery installed.
FAQs
Q: What type of battery does the SMK-43 use?
A: The SMK-43 uses a 9V alkaline battery or carbon battery. The manual recommends replacing the battery with a new one having the same parameters when a low-voltage warning occurs.
Q: How often should the smoke detector be tested?
A: The detector should be tested weekly by pressing the TEST key once. In normal status, the test activates the sound and light alarm and sends a wireless alarm signal.
Q: What is the wireless range of the SMK-43?
A: The manual specifies a wireless distance of ≥100 metres in open space. Actual range may vary depending on walls and other obstacles.
Q: Can the SMK-43 be installed outdoors?
A: No. The manual specifies indoor use and installation only.
Q: Can the SMK-43 be installed in a bathroom?
A: No. The manual specifically states not to install it in bathrooms, water-susceptible areas or locations where water may drip.
Q: What is the alarm sound level?
A: The specified alarm sound is greater than 80 dB.
Spare Parts
-
Spare Part 1: 9V Replacement Battery
Replacement 9V alkaline or carbon battery with the same parameters as the original battery. -
Spare Part 2: Installation / Mounting Plate
Replacement mounting plate for securing the SMK-43 detector to the installation surface. -
Spare Part 3: Mounting Hardware
Replacement self-fastening screws and plastic expansion nuts for screw installation.
Warranty
Warranty Period: 1 Year
The SMK-43 is covered by a 1-year warranty against manufacturing defects under normal use.
The manual specifically states that the detector should be inspected regularly and returned for factory repair if any malfunction is identified. Battery life may be shorter than one year under demanding conditions such as high temperature and high humidity.
Warranty does not cover: physical damage, incorrect installation, improper use, water exposure, unauthorized modification, or damage caused by unsuitable environmental conditions.
Videos
Manuals
- User Manual:

Downloads
- [Datasheet]: Refer to user manual
- [Wiring Diagram]: Refer to user manual
- [Catalogue / Brochure]: NA
- [Other Download]: NA
Customer Questions
Q: What type of battery does the SMK-43 use?
A: The SMK-43 uses a 9V alkaline battery or carbon battery.
Q: What is the wireless operating range of the SMK-43?
A: The specified wireless distance is ≥100 metres in open space.
Q: What wireless frequencies does the SMK-43 support?
A: The manual specifies 433MHz / 1527 / 330K, with the frequency selectable according to the product configuration.
Q: How loud is the smoke detector alarm?
A: The specified alarm sound level is greater than 80 dB.
Q: How often should the SMK-43 be tested?
A: The detector should be tested once every week by pressing the TEST key.
Q: Can the SMK-43 be installed outdoors?
A: No. The manual specifies indoor use and installation only.
Q: Can the SMK-43 be installed near an air conditioner or ventilation fan?
A: The manual recommends keeping the detector at least 150 cm away from ventilation fans, air conditioners and vents.
Q: What happens when the battery voltage becomes low?
A: The detector provides a low-voltage indication. The manual states that the detector sends a wireless low-voltage code, and the LED blinks twice every 90 seconds with two beeps.
Q: What is the working temperature of the SMK-43?
A: The specified working temperature is 0°C to 50°C.
Q: What should I do if the detector malfunctions?
A: The manual recommends carrying out regular inspections and returning the detector for factory repair if a malfunction is identified.
Escalation to Support
If the issue cannot be resolved using the information above, Please contact Navkar Systems at whatsapp Support number: 91384 68548 with the following information:
- Product Model:
- Purchase Date:
- Problem Description:
- Installation Details:
- Photos / Videos:
- Previous Troubleshooting Performed:
Whatsapp us!