Combo-CN276 Fingerprint Access Control with EM Lock – Setup Guide
Setup guide · Combo-CN276
Fit the EM lock, mount the fingerprint reader and exit button, wire the kit and enrol users. Doors open by fingerprint or card.

What’s in the box
- ACBC-SC5H fingerprint and card access controller
- EM-602 EM lock (600 lbs) with armature plate
- SSW-44 exit push button
- DP-08 power supply
Tools you’ll need
- Drill with wood/metal bits
- Screwdriver set
- 86 mm back box for the controller
- Multi-core cable
- Measuring tape and marker
- L, Z or U bracket if your door needs it
Install
- Pick the door and spots.Controller outside the door at a comfortable height. Exit button inside. EM lock on the top corner of the frame, on the opening side.
- Mount the EM lock.Fix the EM-602 to the frame. Fix the armature plate to the door so it sits flat on the lock face when the door closes.
- Mount the controller.Fix the ACBC-SC5H on an 86 mm box at user height and run its cable through the box.
- Mount the exit button.Fix the SSW-44 inside, near the door, where people can reach it easily.
- Wire the kit.Connect the DP-08 supply, EM lock, exit button and controller exactly as shown in the CN276 Installation Guide (PDF below).
- Power on and test.Switch on. The door should lock. Press the exit button: the door should release.
First-time setup
Enrol users
- Enter the controller’s programming mode as shown in the manual. If it uses a default master code, change it first.
- Add each user’s fingerprint or card by following the enrolment steps in the manual.
- Test every user: a registered finger or card opens the door; an unregistered one does not.
- Press the exit button and confirm the door releases.
Daily use
- Place a registered finger flat on the sensor, or hold a card near the reader.
- The door releases. Open it and walk through.
- From inside, press the exit button to leave.
- The door locks again after the set time.
Troubleshooting
| Problem | Try this |
|---|---|
| Fingerprint or card not recognised | Check the user is enrolled. Place the finger flat and steady. Clean the sensor. Re-enrol a dry or worn finger. |
| Door does not unlock after a valid finger | Check power, the controller-to-lock wiring and that the EM lock is mounted correctly. |
| Door does not lock | The armature plate must sit flat on the lock. Check alignment and that the lock is getting power. |
| Exit button does not release | Check the SSW-44 wiring and the controller’s exit input. |
| System has no power | Check the DP-08 supply, its plug and the mains socket. |
| Tamper alarm sounds | The controller has been opened, moved or knocked. Check it is fixed firmly on its back box. |
Safety
- Switch off mains before any wiring.
- An EM lock releases when power fails. If you need the door locked in a power cut, add a backup power supply.
- Every secured door must have a working exit button.
- Keep the power supply indoors and dry.
- Change any default master or admin code on day one.
Manuals, videos and product page
Lock fitting for every door type, brackets, wiring and setup. 14 pages.
Open PDFEM-602 and L, Z, U brackets. 7 pages.
Open PDFInstallation and setup videos for NavKar products.
Watch on YouTubeSpecifications, photos and accessories.
View productStill need help?
1 year warranty against manufacturing defects. The power adapter has no warranty. Damage from wrong wiring, water, physical damage or electrical surges is not covered.
Send us your model, purchase date and a photo or short video of the problem. WhatsApp +91 91384 68548, Mon–Sat 10:00–5:30.
Chat on WhatsAppAll manuals