Combo-CN59 Electronic Lock with Remote – Setup Guide
Setup guide · Combo-CN59
Fit the RML-8K rim lock on your metal main gate, connect the receiver and adapter, and open the gate by remote.

What’s in the box
- RML-8K electronic rim lock with strike
- RR-120143 remote receiver
- 3 remotes (pre-paired)
- DP-04 12 V power adapter
- Computerised keys
- Fitting kit
Tools you’ll need
- Drill with metal bits
- Screwdriver set
- Measuring tape and marker
- Welding machine, if a mounting plate is needed
- 2-core cable from lock to receiver
- Weatherproof box, if the receiver is outdoors
Install
Have a trained electrician or fabricator do the fitting. Mounting on a metal gate may need a welded plate.
- Check the gate.The lock fits on the inside face of the gate, with the strike on the frame. It suits left- and right-hand gates; the latch is reversible.
- Mark and drill.Hold the lock in place and mark the fixing holes and the key cylinder hole. Drill them.
- Fit the key cylinder and lock.Pass the cylinder through from outside, then fix the lock body on the inside with the screws.
- Fit the strike.Fix the strike on the frame so the latch drops in cleanly when the gate closes. Close and open the gate by hand to test.
- Run the cable.Run 2-core cable from the lock to the receiver location, indoors or in a weatherproof box.
- Wire the receiver.Connect the lock wires and the DP-04 adapter to the receiver as shown in the wiring diagram in the manual.
- Power on last.Plug in the adapter only after all wiring is done.
First-time setup
Test the remotes
- The 3 remotes come pre-paired with the receiver.
- Stand near the gate and press a remote once. The latch should release.
- Push the gate open, then let it close. The latch locks again by itself.
- To add more remotes (up to 20 compatible), follow the pairing steps in the manual for the RR-120143 receiver.
Daily use
- Press any remote once to open. Range is 80 to 100 m, less through walls or metal.
- The latch locks again as the gate closes.
- During a power cut, or if a remote is lost, open with the key.
- Press the remote or exit button once, briefly. The lock coil is made for a short pulse. Holding the button too long overheats and burns the coil.
Troubleshooting
| Problem | Try this |
|---|---|
| Remote does not open the lock | Replace the remote battery. Come closer. Check the adapter is plugged in and the receiver has power. |
| Lock clicks but the gate stays shut | The latch is under pressure. Push or pull the gate slightly while pressing the remote. Re-align the strike. |
| Lock does nothing at all | Check the lock wires at the receiver and the adapter output. Have an electrician test the 12 V supply. |
| Range is very short | Move the receiver away from metal sheets and thick walls. Replace remote batteries. |
| Lock was working, now silent after long presses | The coil may be damaged by holding the button too long. Contact support. |
| Key is hard to turn | Check the cylinder is not over-tightened. Add a little graphite powder, not oil. |
Safety
- Switch off and unplug before wiring.
- Keep the adapter and receiver dry.
- Press the remote once, briefly. Never hold it down.
- Keep a key outside the house for emergencies.
Manuals, videos and product page
Installation, wiring, remote pairing and troubleshooting for RML-8K lock kits. 21 pages.
Open PDFInstallation and setup videos for NavKar products.
Watch on YouTubeSpecifications, photos and accessories.
View productStill need help?
Warranty terms are as stated on your bill and on the product page. Keep your bill safe; we need it for any warranty claim. Free technical support is available for installation and setup.
Send us your model, purchase date and a photo or short video of the problem. WhatsApp +91 91384 68548, Mon–Sat 10:00–5:30.
Chat on WhatsAppAll manuals